Motor Protection Switches


Order No.:
81P0105
Manufacturer SKU:
3RV2011-0KA15


Order No.:
81P0107
Manufacturer SKU:
3RV2011-0KA25


Order No.:
81P0108
Manufacturer SKU:
3RV2011-0KA40


Order No.:
81P0109
Manufacturer SKU:
3RV2011-1AA10


Order No.:
81P0110
Manufacturer SKU:
3RV2011-1AA10-0BA0


Order No.:
81P0111
Manufacturer SKU:
3RV2011-1AA15


Order No.:
81P0113
Manufacturer SKU:
3RV2011-1AA20-0BA0


Order No.:
81P0114
Manufacturer SKU:
3RV2011-1AA25


Order No.:
81P0115
Manufacturer SKU:
3RV2011-1AA40
Order No.:
81P0116
Manufacturer SKU:
3RV2011-1BA10
Order No.:
81P0117
Manufacturer SKU:
3RV2011-1BA15


Order No.:
81P0118
Manufacturer SKU:
3RV2011-1BA15-0BA0
Order No.:
81P0119
Manufacturer SKU:
3RV2011-1BA20
Order No.:
81P0120
Manufacturer SKU:
3RV2011-1BA25


Order No.:
81P0121
Manufacturer SKU:
3RV2011-1BA40


Order No.:
81P0122
Manufacturer SKU:
3RV2011-1CA10


Order No.:
81P0123
Manufacturer SKU:
3RV2011-1CA10-0BA0


Order No.:
81P0124
Manufacturer SKU:
3RV2011-1CA15


Order No.:
81P0125
Manufacturer SKU:
3RV2011-1CA15-0BA0


Order No.:
81P0126
Manufacturer SKU:
3RV2011-1CA20
Protect your electric motor effectively with a motor protection switch
The purpose of a motor protection switch (MSS) is to protect electric motors from overload. This can be a form of thermal overload caused by a mechanical overload. But it is also necessary to prevent non-starting or failure of external conductors with the help of a motor protection switch. Monitoring is therefore implemented thermo-mechanically, thermo-electrically or electronically.
Motor-protective circuit breakers are used, for example, with three-phase motors. They always have an overcurrent and a short-circuit current release device, and in some cases also an undervoltage release.
Buy motor protection switches - what to consider?
If you are looking for a suitable motor protection switch, it is important to take a close look at the electric motor to be connected. After all, the choice of the right motor-protective circuit breaker depends on the rated current of the motor. In addition, various standards may have to be observed. For example, if the motor-protective circuit-breaker is to provide overload protection and short-circuit protection for the cable and the motor. In this case, the motor protection switch must be installed at the beginning of the motor allocation in accordance with DIN VDE 0113.
Do you have questions about the motor protection switches in the Bürklin Elektronik online store? Or do you need detailed advice regarding the models shown? Don't hesitate and contact the Bürklin experts via telephone or e-mail! We are here for you and your questions.